We just released the latest stable of the 123\SmartBMS Venus software.
New since v0.9 (previous stable on our website):
-Active BMS control (DVCC)
-123\SmartBMS Manager which is always visible when installed
You can find the latest software and installation instructions here.

123\SmartBMS Manager
The new 123\SmartBMS Manager takes all values from all connected 123\SmartBMS USB cables and combines this information into one “Manager” value. For example, the capacity of each BMS USB bank is summed to one big total capacity.
Note: the 123\SmartBMS only combines banks with the same amount of cells. For example, when you have parallel battery banks
Active BMS control
In previous version, the 123\SmartBMS software only displayed the BMS info on the Victron console/VRM. In this version, the 123\SmartBMS Manager passes the needed Parameters called CCL, CVL and DCL. These parameters tell the Victron at which voltage to charge, with which current, what current to discharge max etc.
Ignoring a BMS
If you have a 123\SmartBMS which you do not want to include in the 123\SmartBMS Manager, for example because you only want to monitor that bank, change the name of that unit to a name starting with an asterisk (*). For example: *Bank 1
This will tell the 123\SmartBMS Manager to avoid this instance.